ASDL-350
Remote access removes boundaries, eliminates the need for time consuming site visits and provides a network infrastructure suitable for today’s “always-on” society. The ADSL-350 is an industrially designed ADSL broadband router built to cope with harsh environments and the characteristics of industrial applications. The unit supports a wide range of ADSL-standards and has support for long lines.
Most devices today comes equipped with an Ethernet port for communications, therefore the ADSL-350 has a built-in two port Ethernet switch. For legacy connectivity the unit also features one RS-232-port to provide multiple connection possibilities for both new and legacy replacement installations. Designed to be installed on a DIN rail all connectors and LEDs have been positioned in the front of the unit, facing the user for easy access and fast status feedback. With the wide power input range the unit can be powered from 10 to 60 VDC and has low power consumption.
The cyber security features of the ADSL-350 prevent unauthorized access and secure the communication for Internet-enabled applications. The easy to use firewall filters incoming traffic, allowing only approved packets to pass through. To inter-connect units with each other securely over the Internet multiple VPN technologies are supported, including IPsec and OpenVPN.
Upgrading legacy solutions to become IP-enabled can prove both costly and tedious therefore the ADSL-350 includes a wide feature set for various legacy applications including both modem replacement methods as well as serial to Ethernet conversion. If there are applications that require extra attention Westermo’s extensive experience from over 35 years within industrial data communications and over 5 years of industrial ADSL expertise will be available to assist you.
ASDL-350
• Product Description | |
Status | Active |
Article number | 3623-0301 |
Ports | 2 x 10 Mbit/s or 100 Mbit/s, Ethernet TX, RJ-45 1 x 300 bit/s to 115.2 kbit/s, RS-232, RJ-45 1 x ADSL, ADSL2/ASDL2+, RJ-11. |
Description | Industrial ADSL Routerv |
• Reliability prediction | |
Service life, operating | 10 years |
• EMC (Electromagnetic Compatibility) | |
EN 55024 + A1 + A2 | Electromagnetic compatibility – Immunity IT equipment |
EN 55022 +A1 | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement |
• EMC specifications | |
EN 61000-4-2, ESD | Enclosure: Contact: ± 6 kV Air: ± 8 kV |
IEC 61000-4-3, RF field AM modulated | Enclosure 10 V/m (crit A)(80 – 2700 MHz) |
EN 61000-4-4, fast transients | Signal ports ± 1 kV (crit A) Power ports ± 2 kV (crit A) |
EN 61000-4-5, surge | Ethernet ports ± 1 kV (direct) (crit A) Power ports ± 0.5 kV (line to earth) (crit A) ± 0.5 kV (line to line) (crit A) |
EN 61000-4-6, conducted RF immunity | All ports 10 V/m, (crit A)(0.15 – 80 MHz) |
EN 55016-2-3, radieted emission | Enclosure Class B |
EN 55022, conducted emission | AC power ports Class B DC power ports Class B Ethernet ports Class B |
• Safety | |
EN 60950-1, dielectric strength | IT equipment |
• Climatic | |
Temperature, operating | –25 to +70°C (–13 to +158°F) |
Temperature, storage | –40 to +85°C (–40 to +185°F) |
Humidity, operating | 0 to 90% relative humidity non condensing. |
Humidity, storage | 0 to 90% relative humidity non condensing. |
• Enclosure | |
Dimensions (W x H x D) | 53 x 103 x 97 mm (2.08 x 4.05 x 3.81 in) |
Weight | 0.4 kg |
Degree of protection | IP 40 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Interface specifications, power | |
Rated voltage | 12 to 48 VDC |
Operating voltage | 10 to 60 VDC |
Rated current | 520 mA @ 12 VDC |
Startup current | 5500 mA @ 12 VDC |
Rated frequency | DC |
• Interface specification, RS-232 | |
Electrical specification | IEEE std 802.3. 2005 Edition |
Data rate | 300 bit/s – 115.2 kbit/s |
Data format | 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits |
Protocol | Transparent, optimised by packing algorithm |
Circuit type | SELV |
Transmission change | 15 m / 49 ft |
Connection | 9 pin D-sub female |
Shielded cable | Not required |
Conductive housing | Yes |
Number of ports | 1 |
• Interface specifications, 10/100 BaseTX | |
Electrical specification | IEEE std 802.3. 2005 Edition |
Data rate | 10 Mbit/s, 100 Mbit/s, manual or auto |
Duplex | Full or half, manual or auto |
Transmission range | 100 m/328 ft |
Isolation to | All other |
Connection | RJ-45 auto MDI/MDIX |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.* |
Conductive housing | Yes |
Number of ports | 2 |
• Interface specifiication, DSL |
|
Data rate | 30 Mbit Downlink, 3 Mbit Uplink |
Protocol | LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA |
Number of ports | 1 |
Connection | RJ-11 |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |