Industrial Ethernet Extender – DDW-120
The Westermo Industrial Ethernet Extender Wolverine DDW-120 series of Ethernet extenders allow cost effective Ethernet networks to be created over long distances, at data rates of up to 15.3 Mbit/s. The SHDSL technology makes it possible to reuse many types of pre-existing copper cables. This can lead to considerable financial savings as expensive fibre cables do not need to be installed. Dependent on cable characteristics, distances up to 15 km (9.3 mi) can be achieved. Configuration of the Westermo Industrial Ethernet Extender Wolverine DDW-120 is performed using only DIP switches, which ensures rapid installation.
The DDW-120 is Westermo Industrial Ethernet Extender designed for use in heavy duty industrial applications. The wide power range, comprehensive diagnostics and TBU transient protection make it ideal for installation and monitoring in industrial applications.
Only industrial grade components are used which gives the Westermo Industrial Ethernet Extender Wolverine DDW-120 an MTBF of 600,000 hours and ensures a long service life. A wide operating temperature range of –40 to +70°C (–40 to +158°F) can be achieved with no moving parts. The Industrial Ethernet Extender Wolverine DDW-120 has been tested both by Westermo and external test houses to meet many EMC, isolation, vibration and shock standards, all to the highest levels suitable for heavy industrial environments and rail trackside applications.
The Westermo Industrial Ethernet Extender Wolverine DDW-120 is transparent for multicast addressing and VLAN packets, allows VPN pass-through for IPsec and can be used with protocols like MODBUS/TCP and Profinet IO. Line diagnostics can be collected using a simple plug-in diagnostic cable allowing the user to determine the quality of the line in use. The link fault forward function helps to transfer indication of media failure onto connected ports to ensure that the Westermo Industrial Ethernet Extender Wolverine DDW-120 can be used in resilient network structures.
DDW-120
• Product Description | |
Status | Active |
Article number | 3621-0110 |
Ports | 1 x 2 positon detachable scerw terminal, 192 kbit/s to 15304 kbit/s 1 x RJ-45, 10 Mbit/s, 100 Mbit/s, manual or auto |
Description | Ethernet SHDSL Extender |
• Approvals | |
Traffic | NEMA TS 2-2003 version 02.06 Traffic Controller Assemblies with NTCIP Requirements |
• Reliability prediction | |
MTBF, operating | 600 000 h, MIL-HDBK- 217F |
Service life, operating | 10 years |
• EMC (Electromagnetic Compatibility) | |
EN 61000-6-2 | Immunity industrial environments |
EN 55024 | Immunity IT equipment |
EN 61000-6-4 | Emission industrial environments |
FCC Part 15 | Class B |
EN 50121-4 | Railway signalling and telecommunications apparatus |
• EMC Specification | |
EN 61000-4-2, ESD | Contact: ± 6 kV Air: ± 8 kV |
IEC 61000-4-3, RF field AM modulated | 10 V/m 80% AM (1 kHz), 80 – 1 000 MHz 20 V/m 80% AM (1 kHz), 80 – 2 000 MHz |
ENV 50204, RF field 900 MHz | 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients | Signal ports: ± 2 kV Power ports: ± 2 kV |
EN 61000-4-5, surge | Signal ports unbalanced: ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced: ± 2 kV line to earth, ± 1 kV line to line Power ports: ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity | Signal ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-8, power frequency magnetic field | 100 A/m, 50 Hz, 16.7 Hz & 0 Hz |
EN 61000-4-9, pulsed magnetic field | 300 A/m, 6.4 / 16 µs pulse |
EN 61000-4-11, Voltage dips and interruption | AC power ports 10 & 5 000 ms, interruption 10 & 500 ms, 30% reduction 100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Voltage dips and interuption | AC power ports, 10 & 5 000 ms, interruption 10 & 500 ms, 30% reduction 100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Mains freq. 50 Hz | Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz | Signal ports, 250 V 50 Hz line to earth |
EN 55022, radiated RF emission | Class B |
FCC part 15, radiated RF emission | Class B |
EN 55022, conducted emission | AC/DC power ports, Class B |
FCC part 15, conducted emission | AC power ports, Class B |
EN 55022, conducted emission | AC/DC power ports, Class B |
• Safety | |
Safety | UL/IEC/CSA/EN |
EN 60950-1,dielectric strength | Signal port to other isolated ports, 2 kVrms 50 Hz 1 min Power port to other isolated ports, 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min (@ rated power <60 V) |
• Climatic | |
Temperature, operating | –40 to +70ºC (–40 to +158ºF) |
Temperature, storage | –40 to +70ºC (–40 to +158ºF) |
Humidity, operating | 5 to 95% relative humidity |
Humidity, storage | 5 to 95% relative humidity |
• Enclosure | |
Enclosure | DDW-120, UL 94, PC / ABS, Flammability class V-1 |
Dimensions (W x H x D) | 35 x 121 x 119 mm |
Weight | 0.2 kg |
Degree of protection | IEC 529, IP 21 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Mechanical | |
IEC 60068-2-6, vibration | 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz |
IEC-60068-2-27, shock | 15 g, 11 ms |
• Interface specifications, power | |
Operating voltage | 10 to 60 VDC |
Rated voltage | 12 to 48 VDC |
Rated current | 240 mA @ 12 VDC 110 mA @ 24 VDC 60 mA @ 48 VDC |
Rated frequency | DC |
Inrush current | 0.23 A2s |
Startup current | 0.65 Apeak |
Polarity | Reverse polarity protected |
Redundant power input | Yes |
Isolation to | All other |
Connection | 2.5 mm jack, use Westermo cable 1211-2027 |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable | Not required |
• Interface specifications, service | |
Electrical specification | TTL level |
Data rate | 115.2 kbit/s |
Data format | 8 data bits, none parity, 1 stop bits, no flow control |
Circuit type | SELV |
Transmission range | 15 m |
Isolation to | All other |
Galvanic connection to | None |
Connection | 2.5 mm jack, use Westermo cable 1211-2027 |
• Interface specifications, DSL | |
Electrical specification | IEEE G.991.2 Annex B |
Data rate | 192 kbit/s to 15304 kbit/s |
Protocol | EFM according to IEEE 802.3-2004 |
Transmission range | According to ITU-T G.991.2 depending on the line quality |
Protection | Overcurrent / overvoltage protection circuit and varistor |
Isolation to | All other |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable | Not required |
Electrical specification | IEEE std 802.3. 2000 Edition |
Data rate | 10 Mbit/s, 100 Mbit/s, manual or auto |
Duplex | Full or half, manual or auto |
Circuit type | SELV |
Transmission range | 100 m |
Isolation to | All other |
Connection | RJ-45 MDI or auto MDI/MDI-X |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails |
Conductive housing | Isolated to all other circuits |
Miscellaneous | If Auto-Neg. is disabled then this interface will be set MDI |
Number of ports | 1 |
DDW-120 EX
• Product Description | |
Status | Active |
Article number | 3621-5110 |
Ports | 1 x 2 positon detachable scerw terminal, 192 kbit/s to 15304 kbit/s 1 x RJ-45, 10 Mbit/s, 100 Mbit/s, manual or auto |
Description | Ethernet SHDSL Extender |
• Approvals | |
Hazardous locations | FM Approvals, Class I, Division 2 |
• Reliability prediction | |
MTBF, operating | 600 000 h, MIL-HDBK- 217F |
Service life, operating | 10 years |
• EMC (Electromagnetic Compatibility) | |
EN 61000-6-2 | Immunity industrial environments |
EN 55024 | Immunity IT equipment |
EN 61000-6-4 | Emission industrial environments |
FCC Part 15 | Class B |
EN 50121-4 | Railway signalling and telecommunications apparatus |
• EMC Specification | |
EN 61000-4-2, ESD | Contact: ± 6 kV Air: ± 8 kV |
IEC 61000-4-3, RF field AM modulated | 10 V/m 80% AM (1 kHz), 80 – 1 000 MHz 20 V/m 80% AM (1 kHz), 80 – 2 000 MHz |
ENV 50204, RF field 900 MHz | 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients | Signal ports: ± 2 kV Power ports: ± 2 kV |
EN 61000-4-5, surge | Signal ports unbalanced: ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced: ± 2 kV line to earth, ± 1 kV line to line Power ports: ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity | Signal ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-8, power frequency magnetic field | 100 A/m, 50 Hz, 16.7 Hz & 0 Hz |
EN 61000-4-9, pulsed magnetic field | 300 A/m, 6.4 / 16 µs pulse |
EN 61000-4-11, Voltage dips and interruption | AC power ports 10 & 5 000 ms, interruption 10 & 500 ms, 30% reduction 100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Voltage dips and interuption | AC power ports, 10 & 5 000 ms, interruption 10 & 500 ms, 30% reduction 100 & 1 000 ms, 60% reduction |
EN 61000-4-16, Mains freq. 50 Hz | Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz | Signal ports, 250 V 50 Hz line to earth |
EN 55022, radiated RF emission | Class B |
FCC part 15, radiated RF emission | Class B |
EN 55022, conducted emission | AC/DC power ports, Class B |
FCC part 15, conducted emission | AC power ports, Class B |
EN 55022, conducted emission | AC/DC power ports, Class B |
• Safety | |
Safety | W-mo, EN 60079-0 and EN 60079-15 |
EN 60950-1,dielectric strength | Signal port to other isolated ports, 2 kVrms 50 Hz 1 min Power port to other isolated ports, 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min (@ rated power <60 V) |
• Climatic | |
Temperature, operating | –40 to +70ºC (–40 to +158ºF) |
Maximum surface temperature | 135°C (temperature class T4) |
Temperature, storage | –40 to +70ºC (–40 to +158ºF) |
Humidity, operating | 5 to 95% relative humidity |
Humidity, storage | 5 to 95% relative humidity |
• Enclosure | |
Enclosure | Cabelec 6141 |
Dimensions (W x H x D) | 34 x 123 x 121 mm (1.33 x 4.84 x 4.76) |
Weight | 0.2 kg |
Degree of protection | IEC 529, IP 21 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Mechanical | |
IEC 60068-2-6, vibration | 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz |
IEC-60068-2-27, shock | 15 g, 11 ms |
• Interface specifications, power | |
Operating voltage | 10 to 60 VDC |
Rated voltage | 12 to 48 VDC |
Rated current | 240 mA @ 12 VDC 110 mA @ 24 VDC 60 mA @ 48 VDC |
Rated frequency | DC |
Inrush current | 0.23 A2s |
Startup current | 0.65 Apeak |
Polarity | Reverse polarity protected |
Redundant power input | Yes |
Isolation to | All other |
Connection | 2.5 mm jack, use Westermo cable 1211-2027 |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable | Not required |
• Interface specifications, service | |
Electrical specification | TTL level |
Data rate | 115.2 kbit/s |
Data format | 8 data bits, none parity, 1 stop bits, no flow control |
Circuit type | SELV |
Transmission range | 15 m |
Isolation to | All other |
Galvanic connection to | None |
Connection | 2.5 mm jack, use Westermo cable 1211-2027 |
• Interface specifications, DSL | |
Electrical specification | IEEE G.991.2 Annex B |
Data rate | 192 kbit/s to 15304 kbit/s |
Protocol | EFM according to IEEE 802.3-2004 |
Transmission range | According to ITU-T G.991.2 depending on the line quality |
Protection | Overcurrent / overvoltage protection circuit and varistor |
Isolation to | All other |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable | Not required |
Electrical specification | IEEE std 802.3. 2000 Edition |
Data rate | 10 Mbit/s, 100 Mbit/s, manual or auto |
Duplex | Full or half, manual or auto |
Circuit type | SELV |
Transmission range | 100 m |
Isolation to | All other |
Connection | RJ-45 MDI or auto MDI/MDI-X |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails |
Conductive housing | Isolated to all other circuits |
Miscellaneous | If Auto-Neg. is disabled then this interface will be set MDI |
Number of ports | 1 |