Ethernet Extender DDW-120 - Industrial Etherner Extender

Industrial Ethernet Extender – DDW-120

Industrial Ethernet Extender Wolverine DDW-120

Industrial Ethernet Extender Wolverine DDW-120

Industrial Ethernet Extender Wolverine DDW-120ex

Industrial Ethernet Extender Wolverine DDW-120ex

 

 


The Westermo Industrial Ethernet Extender Wolverine DDW-120 series of Ethernet extenders allow cost effective Ethernet networks to be created over long distances, at data rates of up to 15.3 Mbit/s. The SHDSL technology makes it possible to reuse many types of pre-existing copper cables. This can lead to considerable financial savings as expensive fibre cables do not need to be installed. Dependent on cable characteristics, distances up to 15 km (9.3 mi) can be achieved. Configuration of the Westermo Industrial Ethernet Extender Wolverine DDW-120  is performed using only DIP switches, which ensures rapid installation.

The DDW-120 is Westermo Industrial Ethernet Extender designed for use in heavy duty industrial applications. The wide power range, comprehensive diagnostics and TBU transient protection make it ideal for installation and monitoring in industrial applications.

Only industrial grade components are used which gives the Westermo Industrial Ethernet Extender Wolverine DDW-120 an MTBF of 600,000 hours and ensures a long service life. A wide operating temperature range of –40 to +70°C (–40 to +158°F) can be achieved with no moving parts. The Industrial Ethernet Extender Wolverine DDW-120 has been tested both by Westermo and external test houses to meet many EMC, isolation, vibration and shock standards, all to the highest levels suitable for heavy industrial environments and rail trackside applications.

The Westermo Industrial Ethernet Extender Wolverine DDW-120 is transparent for multicast addressing and VLAN packets, allows VPN pass-through for IPsec and can be used with protocols like MODBUS/TCP and Profinet IO. Line diagnostics can be collected using a simple plug-in diagnostic cable allowing the user to determine the quality of the line in use. The link fault forward function helps to transfer indication of media failure onto connected ports to ensure that the Westermo Industrial Ethernet Extender Wolverine DDW-120 can be used in resilient network structures.

Featured Product  for Industrial Ethernet Extender


DDW-120

• Product Description
Status Active
Article number 3621-0110
Ports 1 x 2 positon detachable scerw terminal, 192 kbit/s to 15304 kbit/s
1 x RJ-45, 10 Mbit/s, 100 Mbit/s, manual or auto
Description Ethernet SHDSL Extender
• Approvals
Traffic NEMA TS 2-2003 version 02.06
Traffic Controller Assemblies with NTCIP Requirements
• Reliability prediction
MTBF, operating 600 000 h, MIL-HDBK- 217F
Service life, operating 10 years
• EMC (Electromagnetic Compatibility)
EN 61000-6-2 Immunity industrial environments
EN 55024 Immunity IT equipment
EN 61000-6-4 Emission industrial environments
FCC Part 15 Class B
EN 50121-4 Railway signalling and telecommunications apparatus
• EMC Specification
EN 61000-4-2, ESD Contact: ± 6 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated 10 V/m 80% AM (1 kHz), 80 – 1 000 MHz
20 V/m 80% AM (1 kHz), 80 – 2 000 MHz
ENV 50204, RF field 900 MHz 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
EN 61000-4-4, fast transients Signal ports: ± 2 kV
Power ports: ± 2 kV
EN 61000-4-5, surge Signal ports unbalanced: ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced: ± 2 kV line to earth, ± 1 kV line to line
Power ports: ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Signal ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-8, power frequency magnetic field 100 A/m, 50 Hz, 16.7 Hz & 0 Hz
EN 61000-4-9, pulsed magnetic field 300 A/m, 6.4 / 16 µs pulse
EN 61000-4-11, Voltage dips and interruption AC power ports
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
EN 61000-4-16, Voltage dips and interuption AC power ports,
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
EN 61000-4-16, Mains freq. 50 Hz Signal ports, 100 V 50 Hz line to earth
SS 436 15 03, Mains freq. 50 Hz Signal ports, 250 V 50 Hz line to earth
EN 55022, radiated RF emission Class B
FCC part 15, radiated RF emission Class B
EN 55022, conducted emission AC/DC power ports, Class B
FCC part 15, conducted emission AC power ports, Class B
EN 55022, conducted emission AC/DC power ports, Class B
• Safety
Safety UL/IEC/CSA/EN
EN 60950-1,dielectric strength Signal port to other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports, 3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)
• Climatic
Temperature, operating –40 to +70ºC (–40 to +158ºF)
Temperature, storage –40 to +70ºC (–40 to +158ºF)
Humidity, operating 5 to 95% relative humidity
Humidity, storage 5 to 95% relative humidity
• Enclosure
Enclosure DDW-120, UL 94, PC / ABS, Flammability class V-1
Dimensions (W x H x D) 35 x 121 x 119 mm
Weight 0.2 kg
Degree of protection IEC 529, IP 21
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail
• Mechanical
IEC 60068-2-6, vibration 7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
IEC-60068-2-27, shock 15 g, 11 ms
• Interface specifications, power
Operating voltage 10 to 60 VDC
Rated voltage 12 to 48 VDC
Rated current 240 mA @ 12 VDC
110 mA @ 24 VDC
60 mA @ 48 VDC
Rated frequency DC
Inrush current 0.23 A2s
Startup current 0.65 Apeak
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to All other
Connection 2.5 mm jack, use Westermo cable 1211-2027
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required
• Interface specifications, service
Electrical specification TTL level
Data rate 115.2 kbit/s
Data format 8 data bits, none parity, 1 stop bits, no flow control
Circuit type SELV
Transmission range 15 m
Isolation to All other
Galvanic connection to None
Connection 2.5 mm jack, use Westermo cable 1211-2027
• Interface specifications, DSL
Electrical specification IEEE G.991.2 Annex B
Data rate 192 kbit/s to 15304 kbit/s
Protocol EFM according to IEEE 802.3-2004
Transmission range According to ITU-T G.991.2 depending on the line quality
Protection Overcurrent / overvoltage protection circuit and varistor
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required
Electrical specification IEEE std 802.3. 2000 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m
Isolation to All other
Connection RJ-45 MDI or auto MDI/MDI-X
Shielded cable Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to rails
Conductive housing Isolated to all other circuits
Miscellaneous If Auto-Neg. is disabled then this interface will be set MDI
Number of ports 1


DDW-120 EX

• Product Description
Status Active
Article number 3621-5110
Ports 1 x 2 positon detachable scerw terminal, 192 kbit/s to 15304 kbit/s
1 x RJ-45, 10 Mbit/s, 100 Mbit/s, manual or auto
Description Ethernet SHDSL Extender
• Approvals
Hazardous locations FM Approvals, Class I, Division 2
• Reliability prediction
MTBF, operating 600 000 h, MIL-HDBK- 217F
Service life, operating 10 years
• EMC (Electromagnetic Compatibility)
EN 61000-6-2 Immunity industrial environments
EN 55024 Immunity IT equipment
EN 61000-6-4 Emission industrial environments
FCC Part 15 Class B
EN 50121-4 Railway signalling and telecommunications apparatus
• EMC Specification
EN 61000-4-2, ESD Contact: ± 6 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated 10 V/m 80% AM (1 kHz), 80 – 1 000 MHz
20 V/m 80% AM (1 kHz), 80 – 2 000 MHz
ENV 50204, RF field 900 MHz 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz
EN 61000-4-4, fast transients Signal ports: ± 2 kV
Power ports: ± 2 kV
EN 61000-4-5, surge Signal ports unbalanced: ± 2 kV line to earth, ± 2 kV line to line
Signal ports balanced: ± 2 kV line to earth, ± 1 kV line to line
Power ports: ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Signal ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz
Power ports: 10 V 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-8, power frequency magnetic field 100 A/m, 50 Hz, 16.7 Hz & 0 Hz
EN 61000-4-9, pulsed magnetic field 300 A/m, 6.4 / 16 µs pulse
EN 61000-4-11, Voltage dips and interruption AC power ports
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
EN 61000-4-16, Voltage dips and interuption AC power ports,
10 & 5 000 ms, interruption
10 & 500 ms, 30% reduction
100 & 1 000 ms, 60% reduction
EN 61000-4-16, Mains freq. 50 Hz Signal ports, 100 V 50 Hz line to earth
SS 436 15 03, Mains freq. 50 Hz Signal ports, 250 V 50 Hz line to earth
EN 55022, radiated RF emission Class B
FCC part 15, radiated RF emission Class B
EN 55022, conducted emission AC/DC power ports, Class B
FCC part 15, conducted emission AC power ports, Class B
EN 55022, conducted emission AC/DC power ports, Class B
• Safety
Safety W-mo, EN 60079-0 and EN 60079-15
EN 60950-1,dielectric strength Signal port to other isolated ports, 2 kVrms 50 Hz 1 min
Power port to other isolated ports, 3 kVrms 50 Hz 1 min
2 kVrms 50 Hz 1 min (@ rated power <60 V)
• Climatic
Temperature, operating –40 to +70ºC (–40 to +158ºF)
Maximum surface temperature 135°C (temperature class T4)
Temperature, storage –40 to +70ºC (–40 to +158ºF)
Humidity, operating 5 to 95% relative humidity
Humidity, storage 5 to 95% relative humidity
• Enclosure
Enclosure Cabelec 6141
Dimensions (W x H x D) 34 x 123 x 121 mm (1.33 x 4.84 x 4.76)
Weight 0.2 kg
Degree of protection IEC 529, IP 21
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail
• Mechanical
IEC 60068-2-6, vibration 7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
IEC-60068-2-27, shock 15 g, 11 ms
• Interface specifications, power
Operating voltage 10 to 60 VDC
Rated voltage 12 to 48 VDC
Rated current 240 mA @ 12 VDC
110 mA @ 24 VDC
60 mA @ 48 VDC
Rated frequency DC
Inrush current 0.23 A2s
Startup current 0.65 Apeak
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to All other
Connection 2.5 mm jack, use Westermo cable 1211-2027
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required
• Interface specifications, service
Electrical specification TTL level
Data rate 115.2 kbit/s
Data format 8 data bits, none parity, 1 stop bits, no flow control
Circuit type SELV
Transmission range 15 m
Isolation to All other
Galvanic connection to None
Connection 2.5 mm jack, use Westermo cable 1211-2027
• Interface specifications, DSL
Electrical specification IEEE G.991.2 Annex B
Data rate 192 kbit/s to 15304 kbit/s
Protocol EFM according to IEEE 802.3-2004
Transmission range According to ITU-T G.991.2 depending on the line quality
Protection Overcurrent / overvoltage protection circuit and varistor
Isolation to All other
Connection Detachable screw terminal
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required
Electrical specification IEEE std 802.3. 2000 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m
Isolation to All other
Connection RJ-45 MDI or auto MDI/MDI-X
Shielded cable Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close to rails
Conductive housing Isolated to all other circuits
Miscellaneous If Auto-Neg. is disabled then this interface will be set MDI
Number of ports 1

Related Product

GSM Modem be_480px_GDW-11-485
Managed Industrial Ethernet Switch L108-F2G-S2
Managed Industrial Ethernet Switch RFI-18-F16
Managed Industrial Ethernet Switch L210-F2G
Industrial Ethernet Extender DDW-220
Water and wastewater | Road | Rail trackside | On board rail | Oil and Gas | Maritime and offshore | Factory automation | Energy | Building automation
Copyright © Gigantika All Rights Reserved.