Managed Industrial Ethernet Switch - Industrial Networking Solution

Managed Industrial Ethernet Switch – RFR-12-FB

managed_industrial_ethernet_switch_480px_rfr-12-fb

The RFR-12FB has been specially designed to allow the creation of a fault tolerant Ethernet backbone structure in trains. The dual bypass relay ensures that aggregated links between carriages are maintained, even if one carriage has a power failure. The 12 100 Mbit/s Ethernet ports support the extended specification 185 m standard so even if several carriages are bypassed, communication is maintained. The Westermo WeOS operating system provides an extensive suite of IP networking standards allowing resilient and flexible networks to be created, meeting the needs of the rail market.

As is critical for all equipment to be installed in rail vehicles, the RFR-12-FB has been externally tested across the complete spectrum of standards required by EN50155.

Westermo understand that systems on railcars are required by the EN50155 standard to have a useful life of 20 years, so as well as using the highest quality components to deliver extended MTBF figures, we also implement features like the Gor-tex® membrane in the IP65 enclosure to prevent water build up in the units.

The EN50155 standard requires mandatory performance and isolation testing. Not only does Westermo meet these, we exceed them in order to meet the additional manufacturer requirements for train control. Westermo’s Swedish factory has been building Industrial Ethernet switches for the railcar market for many years now and understands the measures that are required to provide the highest quality manufactured solutions.

• Protocols and functionality
Resiliency and high availability Fast Reconfiguration of Network Topology (FRNT)
FRNT Link Health Protocol (FLHP)
IEEE 802.1D Spanning Tree Protocol (STP)
IEEE 802.1w Rapid STP (RSTP)
Layer 2 switching IEEE 802.1Q Static VLAN and VLAN Tagging
IEEE 802.3x Flow Control
IGMPv2/v3 snooping
AVT Dynamic VLAN (Adaptive VLAN Trunking)
Management VLAN (Management Interface concept)
Static Multicast MAC filters
Layer 2 QoS IEEE 802.1p Class of Service
Classification: VLAN tag, VLAN ID, IP DSCP/ToS, Port ID
IP routing, cyber security, firewall and VPN Static IP routing
Dynamic IP routing
• OSPFv2
• RIPv1/v2
Robust VRRP
Stateful Inspection Firewall
• NAT
• 1-1 NAT
• Port Forwarding
• ALG Helpers
IPSec VPN
• IKEv1
• ESP
• VPN failover
GRE
Multinetting
Loopback Interface
TCP MSS Clamping
Manageability Management tools
• Web interface (HTTP and HTTPS)
• CLI via console port and SSHv2 and Telnet
• Westermo IPConfig tool
• SNMPv1/v2c/v3
• Flexible management of configuration and log files
• Secure Copy (SCP)
• Local file management via HTTP, FTP, TFTP and SCP
• Load/save files from/to USB memory stick
Flexible alarm/event handling system
Syslog (log files and remote syslog server)
Digital I/O
Port Monitoring
SNTP (NTP client)
PPPoE client
DHCP client
DHCP server
DHCP relay agent (DHCP option 82)
DDNS
SNMP MIB support RFC1213 MIB-2
RFC2863 Interface MIB (ifXTable)
RFC2819 RMON MIB (etherStatsTable)
RFC4188 Bridge MIB
RFC4318 RSTP MIB
RFC4363 Q-BRIDGE MIB (dot1qVlan and dot1qVlanStaticTable)
RFC4836 MAU MIB (dot3IfMauBasicGroup and dot3IfMauAutoNegGroup)
RFC4133 Entity MIB (entityPhysical)
RFC3433 Entity Sensor MIB
WESTERMO PRIVATE MIB

Managed Industrial Ethernet Switch - Industrial Networking Solution

• Product Description
Status Active
Article number 3641-1630
Ports 12 x 10/100 Mbit/s (4 for bypass capability)
1 x 12 Mbit/s USB
Description Managed EN50155 Backbone Routing Switch
• EMC specifications
EN 61000-4-2, ESD Enclosure contact discharge immunity: ±6 kV
Enclosure air discharge immunity: ±8 kV
IEC 61000-4-3, RF field AM modulated Enclosure RF immunity: 20 V/m, 80 – 2700 MHz
EN 61000-4-4, fast transients Signal port immunity: ±2 kV
Power port immunity: ±2 kV
EN 61000-4-5, surge Power port immunity:
±2 kV (L-E)
±1 kV (L-L)
EN 50155:2001, surge Power port immunity:
±8.4 kV (L-E)
±8.4 kV (L-L)
EN 61000-4-6, conducted RF immunity Signal port immunity:
10 V/m
0.15 – 80 MHz
Power port immunity:
10 V/m
0.15 – 80 MHz
EN 61000-4-8, power frequency magnetic field Enclosure immunity:
300 A/m
0, 16.7, 50 Hz
EN 61000-4-9, pulsed magnetic field Enclosure immunity: 300 A/m
EN-50155, voltage dips and interruption Residual voltage 0%: 10 ms
EN 50155, supply overvoltage and under voltage Overvoltage 140%: 100 ms & 1000 ms
Residual voltage 60%: 100 ms
EN 55011, Limits: EN 50121-3-2,radiated emsission Enclosure measurement:
40 dBμV/m QP
30 – 230 MHz
47 dBμV/m QP
230 – 1000 MHz
EN 55011, Limits: EN 50121-3-2, conducted emission Power port measurement:
99 dBμV QP
0.15 – 5 MHz
93 dBμV QP
5 – 30 MHz
Signal port measurement:
99 dBμV QP
0.15 – 5 MHz
93 dBμV QP
5 – 30 MHz
• EMC (Electromagnetic Compatibility)
EN 50121-3-2 Railway applications – EMC: Rolling stock – Apparatus
EN 50155 Railway applications, Approval/Compliance
• Safety
Safety EN 60950-1, IT equipment
• Reliability prediction
MTBF, operating MIL-HDBK- 217F,operating, 306.000 h
• Climatic
Temperature, operating –40 to +70°C (–40 to +158°F)
Temperature, storage –50 to +85°C (–58 to +185°F)
Maximum surface temperature
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Dimensions (W x H x D) 175 x 100 x 144 mm (6.88 x 3.93 x 5.66 inch)
Weight 2240 g
Degree of protection IP 65
Cooling Convection
Mounting Rear panel wall mounting
• Mechanical
IEC 60068-2-6, vibration Operating:
7.5 mm, 5 – 8 Hz
2 g, 8 – 500 Hz
IEC 60068-2-64, vibration Operating:
Vertical 1.0 m/s² Transverse
1.0 m/s² Longit. 1.0 m/s²
IEC-60068-2-27, shock Operating:
15 g 11 ms, 3 x 6 chocks
• Interface specifications, power
Operating voltage 16.8 to 143 VDC
Rated voltage 20 to 110 VDC
Rated current 580 mA @ 24 VDC
140 mA @ 110 VDC
Inrush current 5 mA²s @ 24 VDC
22 mA²s @ 110 VDC
Startup current 600 mA @ 24 VDC
275 mA @ 110 VDC
(Power source capability)
Polarity Reverse polarity protected
Redundant power input No
Isolation to All interfaces and chassis
Galvanic Connection to None
Connection M12 A-coded male
Connector size 0.2 – 2.5 mm2 (AWG 24 – 12)
Shielded cable Not required
• Interface specifications, 10/100BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate IEEE std 802.3. 2000 Edition
Protocol
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All interfaces and chassis
Galvanic connection to None
Connection M12 D-coded
Shielded cable Yes. Should also be separated from EMI disturbers
Conductive housing Yes
Miscellaneous
Number of ports 12
• Interface specifications, USB
Electrical specification USB
Data rate 12 Mbit/s
Protocol USB v2.0
Connection M12 A-coded female
Isolation to All interfaces, but not to chassis

Related Product

Industrial Unmanaged Ethernet Switch SDW-541
industrial serial converter / repeater 480px_RD-48
Industrial POE Switch Viper-112-212-P8
Industrial Serial Converter be_480px_EDW-120
Managed Industrial Ethernet Switch Viper-408
Water and wastewater | Road | Rail trackside | On board rail | Oil and Gas | Maritime and offshore | Factory automation | Energy | Building automation
Copyright © Gigantika All Rights Reserved.