Managed Industrial Ethernet Switch - Industrial Networking Solution

Managed Industrial Ethernet Switch – VIPER-112

Managed Industrial Ethernet Switch VIPER-112

The Viper-112 is a managed 12 port industrial ethernet switch designed to meet the full requirements of the rail vehicle market. The incredibly compact and robust housing ensures the unit can be built into tight and environmentally hostile spaces. The Westermo WeOS operating system provides an extensive suite of IP networking standards allowing resilient and flexible networks to be created, meeting the needs of the rail market.

As is critical for all equipment to be installed in rail vehicles, the Viper has been externally tested across the complete spectrum of standards required by EN50155.

Westermo understand that systems on railcars are required by the EN50155 standard to have a useful life of 20 years, so as well as using the highest quality components to deliver extended MTBF figures, we also implement features like the Gore-Tex® membrane in the IP65 enclosure to prevent water build up in the units. Due to the high vibration environment of the rail industry, we have also developed the Viper case with integral threading for the M12 connectors to ensure the IP65 seal is maintained for the life of the product.

The EN50155 standard requires mandatory performance and isolation testing. Not only does Westermo meet these, we exceed them in order to meet the additional manufacturer requirements for train control. Westermo’s Swedish factory has been building Ethernet switches for the railcar market for many years now and understands the measures that are required to provide the highest quality manufactured solutions.

Back to Managed Industrial Ethernet Switches

• Protocols and functionality
Resiliency and high availability Fast Reconfiguration of Network Topology (FRNT)
FRNT Link Health Protocol (FLHP)
IEEE 802.1D Spanning Tree Protocol (STP)
IEEE 802.1w Rapid STP (RSTP)
Layer 2 switching IEEE 802.1Q Static VLAN and VLAN Tagging
IEEE 802.3x Flow Control
IGMPv2/v3 snooping
AVT Dynamic VLAN (Adaptive VLAN Trunking)
Management VLAN (Management Interface concept)
Static Multicast MAC filters
Layer 2 QoS IEEE 802.1p Class of Service
Classification: VLAN tag, VLAN ID, IP DSCP/ToS, Port ID
Manageability Management tools
• Web interface (HTTP and HTTPS)
• CLI via console port and SSHv2 and Telnet
• Westermo IPConfig tool
• SNMPv1/v2c/v3
• Flexible management of configuration and log files
• Secure Copy (SCP)
• Local file management via HTTP, FTP, TFTP and SCP
• Load/save files from/to USB memory stick
Flexible alarm/event handling system
Syslog (log files and remote syslog server)
Digital I/O
Port Monitoring
SNTP (NTP client)
PPPoE client
DHCP client
DHCP server
DHCP relay agent (DHCP option 82)
DDNS
SNMP MIB support RFC1213 MIB-2
RFC2863 Interface MIB (ifXTable)
RFC2819 RMON MIB (etherStatsTable)
RFC4188 Bridge MIB
RFC4318 RSTP MIB
RFC4363 Q-BRIDGE MIB (dot1qVlan and dot1qVlanStaticTable)
RFC4836 MAU MIB (dot3IfMauBasicGroup and dot3IfMauAutoNegGroup)
RFC4133 Entity MIB (entityPhysical)
RFC3433 Entity Sensor MIB
WESTERMO PRIVATE MIB
• Product Description
Status Active
Article number 3641-0555
Ports 12 x 10/100BaseTX, M12 contact
1 x USB 2.0 host interface
1 x RS-232, 115.2 kbit/s
Description EN 50155 Routing Switch
• Standard compliance
Environmental EN 61373:1999, Railway applications – Rolling stock equipment. Shock and vibration tests
IEEE1478:2001, Environmental conditions for transit rail car electronic equipment
EN 50124-1: 2001+A1:2003+A2:2005, Railway applications – Insulation coordination
Fire safety standard CEN 45545-2
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ±6 kV
Air: ±8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 20 V/m @ (80 MHz – 2.7 GHz), 1 kHz sine, 80% AM
EN 61000-4-4, fast transients Power port, ±5 kV
Signal ports, ±5 kV
Earth port, ±1 kV
EN 61000-4-5, surge Power port:
L-E: ±0.5 kV, 12 Ω, 9 μF, 1.2/50 μs
L-L: ±0.5 kV, 2Ω, 18 μF, 1.2/50 μs
L-E: ±2 kV, 42 Ω, 0.5 μF, 1.2/50 μs
L-L: ±2 kV, 42Ω, 0.5 μF, 1.2/50 μs
L-E: ±8.4 kV, 100 Ω, 0.05/0.1 μs
L-L: ±8.4 kV, 100 Ω, 0.05/0.1 μs
Ethernet ports:
L-E: ±1 kV, 2 Ω L-E: ±2 kV, 42Ω, 0.5 μF
EN 61000-4-6, conducted RF immunity Power port, 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Ethernet ports, 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port, 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
EN 61000-4-8, power frequency magnetic field Enclosure, 300 A/m; 0, 16.7, 50, 60 Hz
EN 61000-4-9, pulsed magnetic field Enclosure, 300 A/m
IEC 61000-4-3, RF field AM modulated Enclosure, 20 V/m @ (80 MHz – 2.7 GHz), 1 kHz sine, 80% AM
EN 55022, radiated RF emission Enclosure, class B
Power port, class B
Ethernet ports, class B
FCC part 15, radiated RF emission Enclosure, class B
EN 55022, conducted emission DC power port & Ethernet ports, Class B
FCC part 15, conducted emission DC power port, Class B
• EMC (Electromagnetic Compatibility)
EN 61000-6-1 Immunity residential environments
EN 61000-6-2 Immunity industrial environments
EN-50155 Railway applications – Electronic equipment used on rolling stock
EN 55024 Immunity IT equipment
EN 61000-6-3 Emission standard for residential, commercial and light-industrial environments.
EN 61000-6-4 Emission industrial environments
EN 55022 +A1 Emission IT equipment
EN-50121-3-2 Railway applications – EMC: Rolling stock – Apparatus
FCC part 15 Class B
EN 50121-4 Railway signaling and telecommunications apparatus
IEC 62236-4 Railway signalling and telecommunications apparatus
• Safety
Safety EN 60950-1, IT equipment
EN 60950-1, dielectric strength Power port to all other ports, 1.5 kV ACrms, 50 Hz, 1 min
Ethernet ports to all other ports, 1.5 kV ACrms, 50 Hz, 1 min
• Reliability prediction
MTBF, operating 554,000 h, MIL-C217F2, GB, 25°C (77°F)
Service life, operating 15 years
• Climatic
Temperature, operating –40 to +70°C (–40 to +158°F)
Temperature, storage –40 to +70°C (–40 to +158°F)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Zinc, fire enclosure.
Dimensions (W x H x D) 175 x 62.5 x 100 mm (6.9 x 2.5 x 3.9 in)
Weight 1.4kg
Degree of protection IP 65
Cooling Convection
Mounting Wall mounted
• Mechanical
IEC 60068-2-6, vibration Non operating long life simulation, 7.9 m/s² (RMS) 5 – 150 Hz
Vibration, random functional Operating, 1 m/s² (RMS) 5 – 150 Hz
IEC-60068-2-27, shock Operating, 5 g, 30 ms
IEC 60068-2-27, bump Operating, 10 g, 11 ms
• Interface specifications, power
Operating voltage Rated: 24 to 110 VDC Operating: 24 to 110 VDC ± 30%
Operating for 100 ms: 24 to 110 VDC ±40%
Rated current 350 mA @ 24 V and 90 mA @ 110 V
Rated frequency DC
Inrush current 1 mA²s @ 24V and 6 mA²s @ 110V
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to 1500 VAC rms to all other
Connection 4 pin male M12 A-coded connector, use Westermo cable
3146-1106 for 1.5 m
3146-1107 for 5 m
Connector size M12, recommended cable area 0.5 mm² recommended (minimum 0.25 mm²), cable dimensions depend on choice of M12 connector
• Interface specifications, 10/100BaseTX
Electrical specification IEEE IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better
Isolation to Other Ethernet ports, 1500 VAC rms
USB and CON or SRV1 and SRV2, 1500 VAC rms
DC, 1500 VAC rms
Connection 4-pin M12 D-code, auto MDI/MDI-X, use e g Westermo cable
3146-1100 M12-M12 – 1 m
3146-1101 M12-M12 – 5 m
3146-1103 RJ45-M12 – 1 m
3146-1104 RJ45-M12 – 5 m
Shielded cable Not required, but recommended in severe electromagnetic environments
Conductive housing Yes
Number of ports 12
• Interface specifications, USB
Electrical specification USB 2.0 host interface
Data rate Up to 480 Mbit/s (high-speed mode)
Maximum supply current 500 mA
Circuit type SELV
Isolation to Ethernet ports, 1500 VAC rms
DC, 1500 VAC rms
No isolation to CON
Connection 5-pin M12 female A-code, use Westermo USB plug 3641-0190
• Interface specifications, console
Electrical specification RS-232
Data rate 115.2 kbit/s
Data format 8 data bits, no parity, 1 stop bit, no flow control
Circuit type SELV
Isolation to Ethernet ports, 1500 VAC rms
DC, 1500 VAC rms
No isolation to USB
Connection 5-pin M12 female B-code, use Westermo cable 1211-2215

Related Product

industrial modem
GSM Modem be_480px_GDW-11
managed industrial ethernet switch rfi-18-f8
Unmanaged Industrial Ethernet Switch viper-012
Managed Industrial Ethernet Switch RFI-14-F4G-F8
Water and wastewater | Road | Rail trackside | On board rail | Oil and Gas | Maritime and offshore | Factory automation | Energy | Building automation
Copyright © Gigantika All Rights Reserved.