FDV-206-1D-1S
Remote access removes boundaries, eliminates the need for time consuming site visits and provides a network infrastructure suitable for today’s “always-on” society. The Falcon industrial broadband router is the world’s first VDSL2 router designed for use in industrial environments. Due to the fact that many installations are in remote locations the Falcon also supports ADSL, ADSL2, and ADSL2+ to allow access to your applications remotely regardless of their physical location.
The Falcon, incredibly compact and built into a purpose designed case with an integrated DIN rail clip, has an operational temperature between –20 to +70ºC (–4 to 158°F) and is designed to operate in industrial EMC levels. High MTBF figures lead to an expected service life of more than 10 years. The often critical nature of the installations calls for reliability so the Falcon can be powered from separate DC voltages sources with inputs ranging from 19 – 60 VDC.
The Westermo Operating System (WeOS) is a feature rich operating system designed for the industrial markets. It provides the Falcon with cyber security functionality, such as DMZ, IPsec VPNs and a stateful inspection firewall configured to be secure by default. Management is done via an easy-to-use web interface, through an advanced CLI, or via SNMP.
Most industrial devices today have Ethernet communications ports so the Falcon comes equipped with a built in four (4) port layer 3 routing switch. The Falcon can cope with older legacy devices running RS-232 with its built in device server interface, making it perfect for analogue modem replacement projects. One model for ADSL over PSTN or ISDN removes the risk of having to know beforehand what unit to put into what application. Setting up a broadband connection has never been easier using the basic setup page.
WeOS
• Protocols and functionality | |
Resiliency and high availability | Fast Reconfiguration of Network Topology (FRNT) FRNT Link Health Protocol (FLHP) IEEE 802.1D Spanning Tree Protocol (STP) IEEE 802.1w Rapid STP (RSTP) |
Layer 2 switching | IEEE 802.1Q Static VLAN and VLAN Tagging IEEE 802.3x Flow Control IGMPv2/v3 snooping AVT Dynamic VLAN (Adaptive VLAN Trunking) Management VLAN (Management Interface concept) Static Multicast MAC filters |
Layer 2 QoS | IEEE 802.1p Class of Service Classification: VLAN tag, VLAN ID, IP DSCP/ToS, Port ID |
IP routing, cyber security, firewall and VPN | Static IP routing Dynamic IP routing • OSPFv2 • RIPv1/v2 Robust VRRP Stateful Inspection Firewall • NAT • 1-1 NAT • Port Forwarding • ALG Helpers IPSec VPN • IKEv1 • ESP • VPN failover GRE Multinetting Loopback Interface TCP MSS Clamping |
Manageability | Management tools • Web interface (HTTP and HTTPS) • CLI via console port and SSHv2 and Telnet • Westermo IPConfig tool • SNMPv1/v2c/v3 • Flexible management of configuration and log files • Secure Copy (SCP) • Local file management via HTTP, FTP, TFTP and SCP • Load/save files from/to USB memory stick Flexible alarm/event handling system Syslog (log files and remote syslog server) Digital I/O Port Monitoring SNTP (NTP client) PPPoE client DHCP client DHCP relay agent (DHCP option 82) DDNS |
SNMP MIB support | RFC1213 MIB-2 RFC2863 Interface MIB (ifXTable) RFC2819 RMON MIB (etherStatsTable) RFC4188 Bridge MIB RFC4318 RSTP MIB RFC4363 Q-BRIDGE MIB (dot1qVlan and dot1qVlanStaticTable) RFC4836 MAU MIB (dot3IfMauBasicGroup and dot3IfMauAutoNegGroup) RFC4133 Entity MIB (entityPhysical) RFC3433 Entity Sensor MIB WESTERMO PRIVATE MIB |
FDV-206-1D-1S
• Product Description | |
Status | Active |
Article number | 3660-0100 |
Ports | 4 x 10 Mbit/s or 100 Mbit/s, Ethernet TX, RJ-45. 1 x 50 bit/s to 115.2 kbit/s, RJ-45, RS-232. 1 x ADSL, ADSL2/ASDL2+/VDSL2, RJ-11. 1 x USB. |
Description | Industrial Broadband Router |
• EMC (Electromagnetic Compatibility) | |
EN 55024 | Electromagnetic compatibility – Immunity IT equipment |
EN 55024 + A1 + A2 | Electromagnetic compatibility – Immunity IT equipment |
EN 55022 | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. |
EN 55022 +A1 | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. |
EN 61000-6-2 | Immunity industrial environments |
EN 61000-6-4 | Emission industrial environments |
EN 61000-6-3 | Emission residential, commercial and light-industrial environments |
FCC part 15 | Class A and Class B |
EN 50121-4 | Railway signalling and telecommunications apparatus |
• EMC specifications | |
EN 61000-4-2, ESD | Enclosure contact, ± 6 kV Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated | Enclosure, 20 V/m 80% AM (1 kHz), 80 – 2 700 MHz |
EN 61000-4-4, fast transients | Signal ports, ± 2 kV Power ports, ± 2 kV |
EN 61000-4-5, surge | Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity | Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-9, pulsed magnetic field | Enclosure, 300 A/m, 6.4 / 16 μs pulse |
EN 61000-4-29, voltage dips and interruption | DC power ports: 10 & 100 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction +20% above & –20% below rated voltage |
EN 55022, radiated RF emission | Enclosure, class A |
FCC part 15, radiated RF emission | Enclosure, class A |
EN 55022, conducted emission | AC power ports, class B DC power ports, class B |
FCC part 15, conducted emission | AC power ports, class B |
• Safety | |
EN 60950-1, dielectric strength | EN 60950-1, IT equipment |
• Reliability prediction | |
MTBF, operating | 580 000 hours @ 25°C, MIL-HDBK- 217F |
Service life, operating | 10 years |
• Climatic | |
Temperature, operating | –20 to +70ºC (–4 to +158°F) |
Temperature, storage | –40 to +85ºC (–40 to +185°F) |
Humidity, operating | 5 to 95 % relative humidity |
Humidity, storage | 5 to 95 % relative humidity |
• Enclosure | |
Enclosure | UL 94. PC / ABS, flammability class V-1 |
Dimensions (W x H x D) | 53 x 103 x 103 mm (2.08 x 4.05 x 4.05 in) |
Weight | 0.4 kg |
Degree of protection | IP 40 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Mechanical | |
IEC 60068-2-6, vibration | Operating: 5 – 20 Hz: 2 m²/s³ 20 – 200 Hz: – 3 dB/oct 3 axis = 3 * 30 min |
IEC 60068-2-27, shock | Operating: 6 ms 1000 m/s² 6 directions, 3 shocks / direction |
• Interface specifications, power | |
Rated voltage | 24 to 48 VDC |
Operating voltage | 19 to 60 VDC |
Rated current | 460 mA @ 24 VDC 220 mA @ 48 VDC |
Rated frequency | DC |
Inrush current | 1 mA²s @ 24 VDC 3 mA²s @ 48 VDC |
Startup current | 760 mApeak @ 24 VDC 500 mApeak @ 48 VDC |
Polarity | Reverse polarity protected |
Redundant power input | Yes |
Isolation to | All other |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm² (AWG 24 – 12) |
Shielded cable | Not required |
• Interface specification,RS-232 | |
Electrical specification | EIA RS-232 |
Data rate | 300 bit/s to 115.2 kbit/s |
Data format | 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits |
Protocol | Transparent, optimised by packing algorithm |
Circuit type | SELV |
Transmission range | 15 m / 49 ft |
Isolation to | Power, DSL, Ethernet |
Galvanic connection to | USB, Console |
Connection | RJ-45 (RJ-45 to RS-232 converter cable included) |
Shielded cable | Not required |
Conductive housing | Yes |
Number of ports | 1 |
• Interface specifications, 10/100BaseTX | |
Electrical specification | IEEE std 802.3. 2005 Edition |
Data rate | 10 Mbit/s, 100 Mbit/s, manual or auto |
Duplex | Full or half, manual or auto |
Transmission range | 150 m, according to long cable specification |
Isolation to | All other |
Connection | RJ-45 auto MDI/MDIX |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |
Conductive housing | Yes |
Number of ports | 1 |
• Interface specification, console | |
Electrical specification | TTL-level |
Data rate | 115.2 kbit/s |
Data format | 8 data bits, none parity, 1 stop bit, no flow control |
Circuit type | SELV |
Transmission range | 15 m |
Isolation to | Power, DSL, Ethernet |
Galvanic connection to | Serial, USB |
Connection | 2.5 mm jack, use Westermo cable 1211-2027 |
• Interface specifications, USB |
|
Electrical specification | USB 2.0 host interface |
Data rate | Up to 12 Mbit/s (full-speed mode) |
Circuit type | SELV |
Maximum supply current | 500 mA |
Isolation to | Power, DSL, Ethernet |
Galvanic connection to | Serial, Console |
Connection | USB receptacle connector type A |
• Interface specifications, I/O relay output |
|
Connect resistance | 30 Ω |
Isolation to | All other |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm² (AWG 24 -12) |
Maximum voltage / current | 60 VDC / 80 mA |
• Interface specifications, I/O digital input |
|
Voltage levels | Logic one >12V, Logic zero <1V |
Isolation to | All other |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm² (AWG 24 -12) |
• Interface specifications, DSL | |
Electrical specification | See standard table below |
Data rate | 250 Mbit U/D, limited to 100 Mbit |
Protocol | EFM (VDSL2), llc/vc-mux encap Ethernet (ADSL), PPPoE (ADSL / VDSL2) |
Isolation to | All other |
Connection | RJ-11 |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |
Number of ports | 1 |
DSL, Standard/Annex | ETSI TS 101 270 / N/A ITU-T 993.2 (VDSL2) / A, B, J T1.424 / N/A ITU-T G.992.1 (ADSL) / A, B (non overlap) ITU-T G.992.2 (ADSL lite) / A (non overlap) ITU-T G.992.3 (ADSL2) / A, B, I, J, L, M (non overlap) ITU-T G.992.5 (ADSL2+) / A, B, I, J, M (non overlap) ANSI T1.413 / N/A |