Fibre Converter – ODW-730-F2
The ODW-730-F2 has been designed to allow the use of fibre optic cables on RS-422/485 networks. The design allows the use of a range of Westermo verified SFP (Small Form Pluggable) transceivers which can provide solutions with, for example, only a single fibre or distances up to 120 km. Both multidrop networks and redundant rings can be formed using a mixture of transceiver types.
This unit has been designed for industrial use where the requirement is for a long and reliable service life, in a harsh environment. To ensure this reliable operation we manufacture using the highest quality components.
The ODW-730 draws on Westermo’s many years of knowledge of serial protocols and can be used on both synchronous and asynchronous data streams. The switch selectable termination circuit saves the need for external terminating resistors.
Large ring networks can be created to provide network resilience to guarantee system functionality, even if a cable is damaged. The ring recovery time ensures that the network devices are not aware of the failure. The fault contact provides a method to communicate network failures.
ODW-730-F1
• Product Description | |
Status | Active |
Article number | 3651-0732 |
Ports | 1 x Detachable screw terminal, Status 1 x RS-422/485 1 x LC Duplex or LC Simplex, FX (Fibre) |
Description | Point-to-Point Fibre Converter, RS-422/485 |
• Reliability prediction | |
Service life, operating | Operating, 10 years |
• EMC (Electromagnetic Compatibility) | |
EN 61000-6-1 | Immunity residential environments |
EN 61000-6-2 | Immunity industrial environments |
EN 61000-6-3 | Emission residential environments |
EN 61000-6-4 | Emission industrial environments |
EN 55022 | Emission IT equipment, class A |
EN 55024 | Immunity IT equipment |
FCC part 15 | Class A |
EN 50121-4 | Railway signalling and telecommunications apparatus |
IEC 62236-4 | Railway signalling and telecommunications apparatus |
• EMC Specification | |
EN 61000-4-2, ESD | Enclosure contact, ± 6 kV Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated | 10 V/m 80% AM (1 kHz), 80 – 800 MHz 20 V/m 80% AM (1 kHz), 800 – 1000 MHz 20 V/m 80% AM (1 kHz), 1400 – 2700 MHz |
ENV 50204, RF field 900 MHz | Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients | Signal ports, ± 2 kV Power ports, ± 2 kV |
EN 61000-4-5, surge | Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity | Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-9, pulsed magnetic field | Enclosure, 300 A/m, 6.4 / 16 μs pulse |
EN 61000-4-11, Voltage dips and interruption | AC power ports: 10 & 5 000 ms, interruption 200 ms, 40% residual voltage 500 ms, 70% residual voltage |
EN 61000-4-16, Mains freq. 50 Hz | Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz | Signal ports, 250 V 50 Hz line to line |
EN 55022, radiated RF emission | Enclosure, Class B |
FCC part 15, radiated RF emission | Enclosure, Class B |
EN 55022, conducted emission | AC power ports, Class B DC power ports, Class A |
FCC part 15, conducted emission | AC power ports, Class B |
• Safety | |
Safety | UL/CSA/IEC/EN 60950-1, IT equipment |
EN 60950-1,dielectric strength | Signal port to all other isolated ports, 2 kVrms 50 Hz 1min Power port to other isolated ports: 3 kVrms 50 Hz 1min 2 kVrms 50 Hz 1min (@ rated power < 60V) |
• Climatic | |
Temperature, operating | –40 to +60°C (–40 to +140°F) |
Temperature, storage | –40 to +70°C (–40 to +158°F) |
Humidity, operating | 5 to 95% relative humidity |
Humidity, storage | 5 to 95% relative humidity |
• Enclosure | |
Enclosure | UL 94, PC / ABS, Flammability class V-1 |
Dimensions (W x H x D) | 35 x 121 x 119 mm (1.37 x 4.76 x 4.68 in) |
Weight | 0.26 kg |
Degree of protection | IP 21 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Mechanical | |
IEC 60068-2-6, vibration | Operating: 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz |
IEC-60068-2-27, shock | Operating, 15 g, 11 ms |
• Interface specifications, power | |
Operating voltage | 10 to 60 VDC and 20 to 30 VAC |
Rated voltage | 12 to 48 VDC and 24 VAC |
Rated current | 300 mA @ 12 V 150 mA @ 24 V 75 mA @ 48 V |
Rated frequency | DC and 48 to 62 Hz |
Inrush current | 0.2 A²s |
Startup current | 1.0 Apeak |
Polarity | Reverse polarity protected |
Redundant power input | Yes |
Isolation to | RS-485 and Status portt |
Connection | Detachable screw terminal |
Connector size | 0.75 – 2.5 mm² (AWG 18 – 13) Connect the unit using at least 18 AWG (0.75 mm2) wiring |
Shielded cable | Not required |
• Interface specifications, status | |
Port type | Signal relay, changeover contacts |
Rated voltage | Up to 48 VDC |
Operating voltage | Up to 60 VDC |
Contact rating | 500 mA @ 48 VDC |
Contact resistance | < 50 m Ohm |
Isolation to | RS-485 and Power port |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm² (AWG 24 – 13) |
Shielded cable | Not required |
• Interface specifications, RS-422/485 | |
Electrical specification | EIA RS-485, 2-wire or 4-wire twisted pair |
Data rate | 300 bit/s – 1.5 Mbit/s |
Data format | 9 – 12 bits |
Protocol | Start-bit followed by 8-11 bits |
Retiming | Yes |
Turning time | One tbit tbit = 1 / Baud rate (Baud rate in bit/s) |
Transmission range | < 1200 m, depending on data rate and cable type (EIA RS-485) |
Settings | 120 Ohm termination and failsafe biasing 680 Ohm |
Protection | Installation Fault Tolerant (up to ±60 V) |
Isolation to | Status and Power port |
Connection | Detachable screw terminal |
Shielded cable | Not required |
Connector size | 0.2 – 2.5 mm² (AWG 24 – 13) |
ODW-730-F2 EX
• Product Description | |
Status | Active |
Article number | 3651-3732 |
Ports | 1 x Detachable screw terminal, Status 1 x RS-422/485 1 x LC Duplex or LC Simplex, FX (Fibre) |
Description | Point-to-Point Fibre Converter, RS-422/485 |
• Approvals | |
Hazardous locations | ATEX, EN 60079-0 and EN 60079-15 |
• Reliability prediction | |
Service life, operating | Operating,10 years |
• EMC (Electromagnetic Compatibility) | |
EN 61000-6-1 | Immunity residential environments |
EN 61000-6-2 | Immunity industrial environments |
EN 61000-6-3 | Emission residential environments |
EN 61000-6-4 | Emission industrial environments |
EN 55022 | Emission IT equipment, class A |
EN 55024 | Immunity IT equipment |
FCC part 15 | Class A |
EN 50121-4 | Railway signalling and telecommunications apparatus |
IEC 62236-4 | Railway signalling and telecommunications apparatus |
• EMC Specification | |
EN 61000-4-2, ESD | Enclosure contact, ± 6 kV Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated | Enclosure: 10 V/m 80% AM (1 kHz), 80 – 800 MHz 20 V/m 80% AM (1 kHz), 800 – 1000 MHz 20 V/m 80% AM (1 kHz), 1400 – 2700 MHz |
ENV 50204, RF field 900 MHz | Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients | Signal ports, ± 2 kV Power ports, ± 2 kV |
EN 61000-4-5, surge | Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line Power ports, ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity | Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-9, pulsed magnetic field | Enclosure, 300 A/m, 6.4 / 16 μs pulse |
EN 61000-4-11, Voltage dips and interruption | AC power ports: 10 & 5 000 ms, interruptio 200 ms, 40% residual voltage 500 ms, 70% residual voltage |
EN 61000-4-16, Mains freq. 50 Hz | Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz | Signal ports, 250 V 50 Hz line to line |
EN 55022, radiated RF emission | Enclosure, Class B |
FCC part 15, radiated RF emission | Enclosure, Class B |
EN 55022, conducted emission | AC power ports, Class B DC power ports, Class A |
FCC part 15, conducted emission | AC power ports, Class B |
• Safety | |
Safety | EN 60950-1, IT equipment |
EN 60950-1,dielectric strength | Signal port to all other isolated ports, 2 kVrms 50 Hz 1 min Power port to other isolated ports: 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min (@ rated power < 60V) |
• Climatic | |
Temperature, operating | –40 to +60°C (–40 to +140°F) |
Temperature storage | –40 to +70°C (–40 to +158°F) |
Maximum surface temperature | 135°C (temperature class T4) |
Humidity, operating | 5 to 95% relative humidity |
Humidity, storage | 5 to 95% relative humidity |
• Enclosure | |
Enclosure | Cabelec 6141 |
Dimensions (W x H x D) | 35 x 121 x 119 mm (1.37 x 4.76 x 4.68 in) |
Weight | 0.26 kg |
Degree of protection | IP 21 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Mechanical | |
IEC 60068-2-6, vibration | Operating: 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz |
IEC-60068-2-27, shock | Operating, 15 g, 11 ms |
• Interface specifications, power | |
Operating voltage | 10 to 60 VDC and 20 to 30 VAC |
Rated voltage | 12 to 48 VDC and 24 VAC |
Rated current | 300 mA @ 12 V 150 mA @ 24 V 75 mA @ 48 V |
Rated frequency | DC and 48 to 62 Hz |
Inrush current | 0.2 A²s |
Startup current | 1.0 Apeak |
Polarity | Reverse polarity protected |
Redundant power input | Yes |
Isolation to | RS-485 and Status port |
Connection | Detachable screw terminal |
Connector size | 0.75 – 2.5 mm² (AWG 18 – 13) Connect the unit using at least 18 AWG (0.75 mm2) wiring |
Shielded cable | Not required |
• Interface specifications, status | |
Port type | Signal relay, changeover contacts |
Rated voltage | Up to 48 VDC |
Operating voltage | Up to 60 VDC |
Contact rating | 500 mA @ 48 VDC |
Contact resistance | < 50 m Ohm |
Isolation to | RS-485 and Power port |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm² (AWG 24 – 13) |
Shielded cable | Not required |
• Interface specifications, RS-422/485 | |
Electrical specification | EIA RS-485, 2-wire or 4-wire twisted pair |
Data rate | 300 bit/s – 1.5 Mbit/s |
Data format | 9 – 12 bits |
Protocol | Start-bit followed by 8-11 bits |
Retiming | Yes |
Turning time | One tbit tbit = 1 / Baud rate (Baud rate in bit/s) |
Transmission range | < 1200 m, depending on data rate and cable type (EIA RS-485) |
Settings | 120 Ohm termination and failsafe biasing 680 Ohm |
Protection | Installation Fault Tolerant (up to ±60 V) |
Isolation to | Status and Power port |
Connection | Detachable screw terminal |
Shielded cable | Not required |
Connector size | 0.2 – 2.5 mm² (AWG 24 – 13) |