IDW-90
The IDW-90 is an industrial IDSN modem designed to allow cost effective and simple remote access to legacy serial industrial equipment. The AT command driven modem is capable of synchronizing with a wide range of traditional modem negotiation standards providing data rates of up to 128 kbit/s.
With the built-in V.34 analogue modem the IDW-90 can not only connect to ISDN based modems but also with the PSTN units. The unit even has support for V110 which enables GSM-modems to be connected as well. The complete galvanic separation of all interfaces ensures earth loops and transients do not interfere with communication.
Firewalls are not an issue as data does not use the internet and with call back security it is impossible for either accidental or deliberate access to any equipment attached to the modem. To keep visits to the site to a minimum a watchdog monitors the modem ensuring constant readiness, and remote re-configuration means that changes to settings can be handled without a site visit.
The modem is also simple to configure using the Westermo IDW-tool software; standard commands can easily be entered and saved configurations downloaded. RS-232 connections can be made using the standard D-sub whereas the 422/485 connections uses a standard screw terminal. The modem is designed to be connected to devices with no ability to control dialing so special functions like data dialing and DTR dialing are provided to enable these devices to automatically establish connection.
IDW-90
• Product Description | |
Status | Active |
Article number | 3620-0001 |
Ports | 1 x RS-232 1 x RS-422/485 1 x ISDN |
Description | Industrial ISDN Modem |
• Standard compliance | |
ISDN | TBR-3 |
• Reliability prediction | |
Service life, operating | Operating , 10 years |
• EMC (Electromagnetic Compatibility) | |
EN 61000-6-2 | Immunity industrial environments |
EN 55024 | Immunity IT equipment |
EN 61000-6-3 | Emission residential environments |
FCC part 15 | Class B |
EN 50121-4 | Railway signalling and telecommunications apparatus |
IEC 62236-4 | Railway signalling and telecommunications apparatus |
• EMC specifications | |
EN 61000-4-2, ESD | Enclosure contact, ± 6 kV Enclosure air, ± 8 kV |
IEC 61000-4-3, RF field AM modulated | Enclosure: 10 V/m 80% AM (1 kHz), 80 – 1 000 MHz 20 V/m 80% AM (1 kHz), 80 – 2 000 MHz |
ENV 50204, RF field 900 MHz | Enclosure, 20 V/m pulse modulated 200 Hz, 900 ± 5 MHz |
EN 61000-4-4, fast transients | Signal ports, ± 2 kV Power ports, ± 2 kV |
EN 61000-4-5, surge | Signal ports unbalanced, ± 2 kV line to earth, ± 2 kV line to line Signal ports balanced, ± 2 kV line to earth, ± 1 kV line to line Power ports ± 2 kV line to earth, ± 2 kV line to line |
EN 61000-4-6, conducted RF immunity | Signal ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz Power ports, 10 V 80% AM (1 kHz), 0.15 – 80 MHz |
EN 61000-4-8, power frequency magnetic field | Enclosure, 100 A/m, 50 Hz, 16.7 Hz & 0 Hz |
EN 61000-4-9, pulsed magnetic field | Enclosure, 300 A/m, 6.4 / 16 ms pulse |
EN 61000-4-16, Mains freq. 50 Hz | Signal ports, 100 V 50 Hz line to earth |
SS 436 15 03, Mains freq. 50 Hz | Signal ports, 250 V 50 Hz line to line |
EN 61000-4-29, voltage dips and interruption | DC power ports: 10 & 100 ms, interruption 10 ms, 30% reduction 10 ms, 60% reduction+20% above & –20% below rated voltage |
EN 55022, radiated RF emission | Enclosure, class B |
FCC part 15, radiated RF emission | Enclosure, class B |
EN 55022, conducted emission | DC power ports, class B |
• Safety | |
Safety | EN 60950-1, IT equipment |
EN 60950-1, dielectric strength | Signal port to other isolated ports, 2 kVrms 50 Hz 1 min Power port to other isolated ports 3 kVrms 50 Hz 1 min 2 kVrms 50 Hz 1 min (@ rated power <60 V) |
• Climatic | |
Temperature, operating | +5 to +55ºC (+41 to +131ºF) |
Temperature, storage | –20 to +85ºC (–13 to +185ºF) |
Humidity, operating | 5 to 95 % relative humidity |
Humidity, storage | 5 to 95 % relative humidity |
• Enclosure | |
Enclosure | UL 94, PC / ABS, flammability class V-1 |
Dimensions (W x H x D) | 34 x 123 x 121 mm (1.33 x 4.84 x 4.76) |
Weight | 0.21 kg |
Degree of protection | IP 21 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Mechanical | |
IEC 60068-2-6, vibration | Operating, 7.5 mm, 5 – 8 Hz 2 g, 8 – 500 Hz |
IEC-60068-2-27, shock | Operating, 15 g, 11 ms |
• Interface specifications, power | |
Rated voltage | 12 to 48 VDC 12 to 34 VAC |
Operating voltage | 10 to 60 VDC 10 to 42 VAC |
Rated current | 110 mA @ 12 VDC 55 mA @ 24 VDC 30 mA @ 48 VDC |
Rated frequency | DC / AC 48 – 62 Hz |
Inrush current | 0.22 A2s |
Startup current | 0.30 Apeak |
Polarity | Polarity independent |
Isolation to | All other ports 3 kVrms 50 Hz 1 min |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable | Not required |
• integrated Service Digital Network | |
Electrical specification | ISDN BRI: ITU-T I.430 |
Data rate | 300 bit/s – 128 kbit/s |
Protocol | Euro ISDN /DSS1, Leased line B1 / B2 V.110 asynchronous, HDLC async to sync, HDLC transparent, Byte transparent X.75- SLP, V.120, X.31 B channel, X.31 D channel, ML-PPP |
Protection | Installation Fault Tolerant (up to ±60 V) |
Isolation to | Power port 3 kVrms 50 Hz 1 min RS-232 2 kVrms 50 Hz 1 min RS-485 2 kVrms 50 Hz 1 min I/O 2 kVrms 50 Hz 1 min |
Connection | RJ-45 |
Shielded cable | Not required |
• Interface specifications, RS-232 | |
Electrical specification | EIA/TIA-232 |
Data rate | 1 200 bit/s – 115.2 kbit/s |
Data format | 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits; Σ 9 – 12 bits |
Protocol | Transparent |
Retiming | Yes |
Transmission range | Cable length ≤15 m / 49 ft |
Isolation to | Power port 3 kVrms 50 Hz 1 min ISDN line 2 kVrms 50 Hz 1 min I/O 1.5 kVrms 50 Hz 1 min |
Galvanic connection to | RS-485 |
Connection | 9-pin D-sub female (DCE) |
Shielded cable | Not required |
Miscellaneous | Do not connect RS-232 and RS-422/485 simultaneously |
• Interface specifications, RS-422/485 | |
Electrical specification | EIA RS-485 2-wire or 4-wire twisted pair |
Data rate | 300 bit/s to 115.2 kbit/s |
Data format | 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits, Σ 9 – 12 bits |
Protocol | Transparent |
Retiming | Yes |
Turning time | 50 μs (half duplex) |
Transmission range | <1200 m, depending on data rate and cable type (EIA RS-485) |
Settings | 120 Ω termination and failsafe biasing 680 Ω |
Protection | Installation Fault Tolerant (up to ±60 V) |
Isolation to | Power port 3 kVrms 50 Hz 1 min ISDN 2 kVrms 50 Hz 1 min I/O 2 kVrms 50 Hz 1 min |
Galvanic connection to | RS-232 |
Connection | Detachable screw terminal |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Shielded cable | Not required |
Miscellaneous | Not required |
• Interface specifications, I/O Digital input | |
Electrical specification | Opto isolated input |
Input voltage range | 0 – 60 VDC |
Input current | 5 mA @ 60 VDC |
Input inactive | Uin <2.5 V |
Input active | Uin >5.0 V |
Transmission range | Cable Length ≤ 15 m |
Connection | Detachable screw terminal (DCE) |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Isolation to | Power port 3 kVrms 50 Hz 1 min ISDN line 2 kVrms 50 Hz 1 min RS-232 2 kVrms 50 Hz 1 min RS-485 2 kVrms 50 Hz 1 min I/O output 2 kVrms 50 Hz 1 min |
Shielded cable | Not required |
• Interface specifications, I/O relay output | |
Electrical specification | One change over contact |
Switching voltage | Max 40 VAC/DC |
Switching current | Max 500 mA AC/DC |
Electrical endurance | 5 x 105 operations @ 20 W / 20 VA Resistive load |
Transmission range | Cable Length ≤15 m |
Connection | Detachable screw terminal (DCE ) |
Connector size | 0.2 – 2.5 mm2 (AWG 24 – 12) |
Isolation to | Power port 3 kVrms 50 Hz 1 min ISDN line 2 kVrms 50 Hz 1 min RS-232 1.5 kVrms 50 Hz 1 min RS-485 1.5 kVrms 50 Hz 1 min I/O input 2 kVrms 50 Hz 1 min |
Shielded able | Not required |