Industrial Serial Converter – MDW-45
The Industrial Serial Converter MDW-45 is a simple serial converter allowing RS-232 and RS-422/RS-485 systems to be connected. DIP switches are used for all configuration options which makes the unit simple to install.
The MDW-45 is designed for use in heavy duty industrial applications. The wide power range, galvanic isolation, transient protection and the design of the termination and fail safe guarantees communication in the worst environments.
Only industrial grade components are used which gives the MDW-45 an MTBF of 1,000,000 hours and ensures a long service life. A wide operating temperature range of –40 to +70°C (–40 to +158°F) is achieved using no moving parts.
The MDW-45 has been tested both by Westermo and external test houses to meet many EMC, isolation, vibration and shock standards, all to the highest levels suitable for heavy industrial environments and rail trackside applications.
The configurable design of the converter makes the MDW-45 suitable for a variety of applications with various speed and data bit options. Normally RS-485 data direction is controlled by the RS-232 handshaking lines however the MDW-45 also features an automatic turning time function allowing the unit to operate in any application.
MDW-45
• Power | |
Operating voltage | LV : 9.6 to 57.6 VDC HV : 85.5 to 264 VAC or 88 to 300 VDC |
Rated current | LV : 95 mA @ 12 VDC or 35 mA @ 48 VDC HV : 21 mA @ 95 VAC or 10 mA ti 110 VDC |
• Interfaces | |
RS-422/485 |
1 x 4-position detachable screw terminal, 300 bit/s to 115.2 kbit/s
|
RS-232 |
1 x 9-pin D-sub, 1200 bit/s to 115.2 kbit/s
|
• Temperature | |
Operating | –40 to +70°C (–40 to +158°F) |
Storage and transport | –40 to +70°C (–40 to +158°F) |
• EMC specification | |
EN 55024 | Immunity IT equipment |
EN 61000-6-2 | Immunity industrial environments |
EN 61000-6-3 | Emssion residental environments |
FCC Part 15 | Class B |
EN 50121-4 | Railway signalling and telecommunications apparatus |
IEC 62236-4 | Railway signalling and telecommunications apparatus |
• Safety | |
Safety | EN 60950, IT equipment |
• Enclosure | |
Dimension (W x H x D) | 34 x 123 x 121 mm (1.33 x 4.84 x 4.76 |
Weight | 0.19 kg |
Degree of protection | IP21 |
TDW-36 AV/LV
• Power | ||
Operating voltage |
|
|
Rated current |
|
|
• Interfaces | ||
RS-422/485 |
1 x 4-position detachable screw terminal, 300 bit/s to 115.2 kbit/s
|
|
RS-232 |
1 x 9-pin D-sub, 1200 bit/s to 115.2 kbit/s
|
|
• Temperature | ||
Operating | –40 to +70°C (–40 to +158°F) | |
Storage and transport | –40 to +70°C (–40 to +158°F) | |
Maximum surface temperature |
135ºC (275ºF) (temperature class T4)
|
|
• EMC specification | ||
EN 55024 | Immunity IT equipment | |
EN 61000-6-2 | Immunity industrial environments | |
EN 61000-6-3 | Emssion residental environments | |
FCC Part 15 | Class B | |
EN 50121-4 | Railway signalling and telecommunications apparatus | |
IEC 62236-4 | Railway signalling and telecommunications apparatus | |
• Safety | ||
Safety | EN 60950, IT equipment | |
ATEX |
EN 60079-0 and EN 60079-15
|
|
• Enclosure | ||
Dimension (W x H x D) | 34 x 123 x 121 mm (1.33 x 4.84 x 4.76 | |
Weight | 0.19 kg | |
Degree of protection | IP21 |