Viper-112-T3G-P8
The Viper-112-T3G-P8 is a managed 12 port switch including 3 GigE copper connections designed to meet the full requirements of the rail vehicle market. The Viper is capable of delivering up to 61.6 W of power across 8 of the ports, derived from the wide operating DC voltage of the unit. The Westermo WeOS operating system provides an extensive suite of IP networking standards allowing resilient and flexible networks to be created, meeting the needs of the rail market.
As is critical for all equipment to be installed in rail vehicles, the Viper has been externally tested across the complete spectrum of standards required by EN50155. A unique feature of the Viper is the galvanic isolation provided between the input DC voltage and the power delivered through PoE to the connected equipment.
Westermo understand that systems on railcars are required by the EN50155 standard to have a useful life of 20 years, so as well as using the highest quality components to deliver extended MTBF figures, we also implement features like the GORE-TEX® membrane in the IP65 enclosure to prevent water build up in the units. Due to the high vibration environment of the rail industry, we have also developed the Viper case with integral threading for the M12 connectors to ensure the IP65 seal is maintained for the life of the product.
The EN50155 standard requires mandatory performance and isolation testing. Not only does Westermo meet these, we exceed them in order to meet the additional manufacturer requirements for train control. Westermo’s Swedish factory has been building Ethernet switches for the railcar market for many years and fully understands the measures that are required to provide the highest quality manufactured solutions.
Meeting the requirements of the railcar environment, makes the Viper very well suited for deployment in any application with severe operating conditions and extreme environments
WeOS 100-software
• Protocols and functionality | |
Resiliency and high availability | Fast Reconfiguration of Network Topology (FRNT) FRNT Link Health Protocol (FLHP) IEEE 802.1D Spanning Tree Protocol (STP) IEEE 802.1w Rapid STP (RSTP) |
Layer 2 switching | IEEE 802.1Q Static VLAN and VLAN Tagging IEEE 802.3x Flow Control IGMPv2/v3 snooping AVT Dynamic VLAN (Adaptive VLAN Trunking) Management VLAN (Management Interface concept) Static Multicast MAC filters |
Layer 2 QoS | IEEE 802.1p Class of Service Classification: VLAN tag, VLAN ID, IP DSCP/ToS, Port ID |
Manageability | Management tools • Web interface (HTTP and HTTPS) • CLI via console port and SSHv2 and Telnet • Westermo IPConfig tool • SNMPv1/v2c/v3 • Flexible management of configuration and log files • Secure Copy (SCP) • Local file management via HTTP, FTP, TFTP and SCP • Load/save files from/to USB memory stick Flexible alarm/event handling system Syslog (log files and remote syslog server) Digital I/O Port Monitoring SNTP (NTP client) PPPoE client DHCP client DHCP relay agent (DHCP option 82) DDNS |
SNMP MIB support | RFC1213 MIB-2 RFC2863 Interface MIB (ifXTable) RFC2819 RMON MIB (etherStatsTable) RFC4188 Bridge MIB RFC4318 RSTP MIB RFC4363 Q-BRIDGE MIB (dot1qVlan and dot1qVlanStaticTable) RFC4836 MAU MIB (dot3IfMauBasicGroup and dot3IfMauAutoNegGroup) RFC4133 Entity MIB (entityPhysical) RFC3433 Entity Sensor MIB WESTERMO PRIVATE MIB |
• Power | |
Rated voltage | 48 to 110 VDC |
Operating voltage | 33.6 to 143 VDC (28.8 to 154 VDC for 100 ms) |
Rated current | Max 1.8 A @ 48 V, Max 0.8 A @ 110 V @ full PoE load |
Rated output power | Max 61.6 W ±7% distributed on all PoE ports Max 30.8 W on one single PoE port |
• Interfaces | |
X1-X12, Ethernet ports | 9 x 10/100 Mbit/s (8 with PoE capability), 3 x 10/100/1000 Mbit/s |
USB | 1xUSB 2.0,480 Mbit/s |
CON | 1 x RS-232, 115.2 kbit/s |
• Temperature | |
Operating | –40 to +70°C (–40 to +158°F) |
Storage and Temperature | –50 to +85°C (–58 to +185°F) |
• Agency approvals and standard compliance | |
EMC | EN 61000-6-1, Immunity residential environments EN 61000-6-2, Immunity industrial environments EN 61000-6-4, Emission industrial environments EN 55024, Immunity IT Equipment FCC Part 15 Class A EN 50121-4/IEC 62236-4, Railway signaling and telecommunications apparatus EN 50121-3-2 Railway applications – Rolling stock – apparatus EN 55022, Emission IT Equipment |
Safety | IEC/EN 60950-1 IT, equipment |
Environmentals | EN 50155 Railway applications – Electronic equipment used on rolling stock EN 61373 – Railway applications – Rolling stock equipment. Shock and vibration tests IEEE 1478 – Environmental conditions for transit rail car electronic equipment EN 50124-1 – Railway applications – Insulation coordination IEC 60068-2-27, (shock 100 g. 6 ms), IEC 60068-2-64 |