Wireless Router – MRD-350
Remote access removes boundaries, eliminates the need for time consuming site visits and provide a network infrastructure suitable for today’s “always-on” society. The Industrial Wireless Router MRD-350 industrial mobile broadband GPRS / EDGE / 3G router uses the Internet to cost effectively inter-connect systems, allowing HMI, PLCs, sensors etc to communicate with each other.
A compact design bundled with all interfaces and LEDs in the front make the unit extremely well suited for industrial applications. With isolation between the PSU and the Ethernet and serial ports the MRD-350 protects against issues caused by ground loops.
The dual SIM support in the device ensures that site connectivity is not dependent on a single carrier, should something happen the unit just switches to the other SIM.
Devices connected to the Internet require countermeasures towards cyber threats. The MRD-350 offers protection of transmissions from malicious eavesdroppers via encrypted communication tunnels (VPN), and features a simple, yet powerful, packet inspection firewall.
For solar powered applications energy efficiency is vital and the MRD-350 has a special low-power mode to only be fully powered when needed. The MRD-350 with its built-in serial port offers a simple modem replacement solution with the benefit of not having to reprogram or change any other component.
MRD-350
• Product Description | |
Status | Active |
Article number | 3623-0201 |
Ports | 2 x 10 Mbit/s or 100 Mbit/s, Ethernet TX, RJ-45. 1 x 300 bit/s to 115.2 kbit/s, D-sub, RS-232. 2 x SIM slots. |
Description | Industrial mobile broadband / 3G router/ GPRS / EDGE / 3G / HSPA |
• Standard compliance | |
R&TTE | Article 3.1a: EN 60950, Safety EN 50385, EMF exposure Article 3.1b: EN 301 489-1, ERM/EMC EN 301 489-7, ERM/EMC GSM EN 301 489-24, ERM/EMC 3G Article 3.2: EN 301 908-1, ERM 3G EN 301 908-2, ERM 3G EN 301 511, GSM |
• Reliability prediction | |
Service life, operating | 10 year |
• EMC (Electromagnetic Compatibility) | |
EN 55024 | Electromagnetic compatibility – Immunity IT equipment |
EN 55024 + A1 + A2 | Electromagnetic compatibility – Immunity IT equipment |
EN 55022 | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. |
EN 55022 +A1 | Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement. |
• EMC specifications | |
EN 61000-4-2, ESD | Enclosure contact, ± 4 kV (crit A) Enclosure air, ± 8 kV (crit A) |
IEC 61000-4-3, RF field AM modulated | Enclosure, 10 V/m (crit A), (80 – 2700 MHz) |
EN 61000-4-4, fast transients | Signal ports, ± 1 kV (crit A) Power ports, ± 2 kV (crit A) |
EN 61000-4-5, surge | Ethernet ports, ± 1 kV (direct) (crit A) Power ports, ± 0.5 kV (line to earth) (crit A), ± 0.5 kV (line to line) (crit A) |
EN 61000-4-6, conducted RF immunity | All ports, 10 V/m, (crit A), 0.15 – 80 MHz) |
EN 55022, radiated RF emission | Enclosure, Class B |
EN 55022, conducted emission | AC power ports, class B DC power ports, class B Ethernet ports, class B |
• Safety | |
Safety | IEC/EN 60950-1, IT equipment |
• Climatic | |
Temperature, operating | –30 to +60ºC (–22 to +140ºF) |
• Enclosure | |
Dimensions (W x H x D) | 53 x 103 x 103 mm (2.08 x 4.05 x 4.05 in) |
Weight | 0.4 kg |
Degree of protection | IP 40 |
Cooling | Convection |
Mounting | Horizontal on 35 mm DIN-rail |
• Interface specifications, power | |
Rated voltage | 12 – 48 VDC |
Operating voltage | 10 – 60 VDC |
Rated current | 370 mA @ 12 VDC |
Startup current | 1000 mA @ 12 VDC |
Rated frequency | DC |
Consumption guidance/Voltage/Mode/Consumtion | 12 VDC / GPRS Idle / 165 mA 24 VDC / GPRS Idle / 90 mA 48 VDC / GPRS Idle / 55 mA 12 VDC / GPRS Send / 240 mA 24 VDC / GPRS Send / 130 mA 48 VDC / GPRS Send / 75 mA 12 VDC / 3G Idle / 225 mA 24 VDC / 3G Idle / 120 mA 48 VDC / 3G Idle / 70 mA 12 VDC / 3G Send / 275 mA 24 VDC / 3G Send / 155 mA 48 VDC / 3G Send / 80 mA 12 VDC / 3G Send&Receive / 330 mA |
• Interface specification,RS-232 | |
Electrical specification | EIA/TIA-232 |
Data rate | 300 bit/s – 115.2 kbit/s |
Data format | 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits |
Protocol | Transparent, optimised by packing algorithm |
Circuit type | SELV |
Transmission range | 15 m / 49 ft |
Connection | 9 pin D-sub female |
Shielded cable | Not required |
Conductive housing | Yes |
Number of ports | 1 |
• Interface specifications, 10/100 BaseTX | |
Electrical specification | IEEE std 802.3. 2005 Edition |
Data rate | 10 Mbit/s, 100 Mbit/s, manual or auto |
Duplex | Full or half, manual or auto |
Circuit type | SELV |
Transmission range | 100 m/328 ft |
Isolation to | All other |
Connection | RJ-45 auto MDI/MDIX |
Shielded cable | Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails. |
Conductive housing | Yes |
Number of ports | 1 |
• Interface specification, Antenna | |
Frequency bands | GSM / GPRS / EDGE, 850 / 900 / 1800 / 1900 MHz 3G / HSDPA / HSUPA / HSPA, 850 / 900 / 2100 MHz |
Main Antenna | Antenna connector labeled ANT (TX / RX) |
Optional Antenna | Antenna connector labeled AUX, receive diversity (RX only) |
Connection | SMA female, impedance: 50 ohm |
• Interface specification, SIM | |
Electrical specification | 3 volts SIM supported |
Number of slots | 2 |