DR-260 Series - Industrial Networking Solutions – Industrial Ethernet Switches and Routers

DR-260 Series

be_480px_DR-260

 

Remote access removes boundaries, eliminates the need for time consuming site visits and provide a network infrastructure suitable for today’s “always-on” society. The DR-260 ADSL router uses the Internet to cost effectively inter-connect systems, allowing HMI, PLCs, sensors etc to communicate with each other.

The optional multiple media interfaces ensures high availability for critical applications. Mobile broadband (3G) in conjunction with ADSL protects against digging accidents or other issues that may occur in a wired environment.

Devices connected to the Internet require countermeasures towards cyber threats. The DR-260 offers protection of transmissions from malicious eavesdroppers via encrypted communication tunnels (VPN), access prevention from unauthorized addresses, and extensive logging to detect intrusion attempts. With an advanced and highly configurable firewall the unit is easily set up to only allow valid application data.

Certain carriers discontinue leased line service to its customers but that does not mean that the need for communication has changed.

The DR-260 with its built-in serial port offers a simple solution, modem replacement, with the benefit of not having to reprogram or change any other component.

The powerful software in the DR-260 offers methods to engineers to easily analyze the data-flow, valuable for fast troubleshooting of connected devices.

DR-260A

• Product Description
Status Active
Article number 3622-0210
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex A
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 6 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +70ºC (–4 to +158ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 151 mm (9.4 x 1.6 x 5.9 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Conductive housing Yes
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+)  /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260A + 3G

• Product Description
Status Active
Article number 3622-0220
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex A + 3G backup
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 6 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +55ºC (–4 to +131ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 159 mm (9.4 x 1.6 x 6.2 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable RJ-45 auto MDI/MDIX
Conductive housing Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260A + 3G + PSTN

• Product Description
Status Active
Article number 3622-0230
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex A + 3G backup &PSTN backup
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 4 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +55ºC (–4 to +131ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 159 mm (9.4 x 1.6 x 6.2 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or flat on level surface
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable RJ-45 auto MDI/MDIX
Conductive housing Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260B

• Product Description
Status Active
Article number 3622-0240
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex B
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 4 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +70ºC (–4 to +158ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 151 mm (9.4 x 1.6 x 5.9 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or flat on level surface
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Conductive housing Yes
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260B+3G

• Product Description
Status Active
Article number 3622-0250
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex B +3G backup
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 4 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +55ºC (–4 to +131ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 159 mm (9.4 x 1.6 x 6.2 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or flat on level surface
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Conductive housing Yes
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260B + 3G+ISDN

• Product Description
Status Active
Article number 3622-0260
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex B + 3G backup & ISDN backup
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 4 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +55ºC (–4 to +131ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 159 mm (9.4 x 1.6 x 6.2 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or flat on level surface
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable RJ-45 auto MDI/MDIX
Conductive housing Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260B + ISDN

• Product Description
Status Active
Article number 3622-0270
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex B + ISDN backup
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 4 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +55ºC (–4 to +131ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 159 mm (9.4 x 1.6 x 6.2 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or flat on level surface
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Conductive housing Yes
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

DR-260A +PSTN

• Product Description
Status Active
Article number 3622-0280
Ports 4 x 10/100 Base-TX: RJ-45
1 x RS-232: 25-pos. D-sub
Description Multiple Media Router ADSL for Annex A + 3G & PSTN backup
• Approvals
Traffic
• Staandard compliance
R&TTE Article 3.1a:
EN 60950, safety
EN 50385, EMF exposure
Article 3.1b:
EN 301 489-1, ERM/EMC
EN 301 489-7, ERM/EMC GSM
EN 301 489-24, ERM/EMC 3G
Article 3.2
EN 301 908-1, ERM 3G
EN 301 908-2, ERM 3G
EN 301 511, GSM
• Reliability prediction
MTBF, operating 131 400 hours, Bellcore RQGR at 40°C
• EMC (Electromagnetic Compatibility)
EN 55024 Electromagnetic compatibility – Immunity IT equipment
EN 55024 +A1 +A2 Electromagnetic compatibility – Immunity IT equipment
EN 55022 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
EN 55022 +A1 Information technology equipment. Radio disturbance characteristics. Limits and methods of measurement
FCC part 15 Class B
• EMC specifications
EN 61000-4-2, ESD Enclosure:
Contact: ± 6 kV
Air: ± 8 kV
IEC 61000-4-3, RF field AM modulated Enclosure, 3 V/m 80% AM (1 kHz), 80 – 1 000 MHz, 1 400 MHz – 2 000
EN 61000-4-4, fast transients Signal ports, ± 0.5 kV
Power ports, ± 1 kV
EN 61000-4-5, surge Telecom/Signal ports, ± 0.5 kV line to earth
Power ports, ± 2 kV line to earth, ± 2 kV line to line
EN 61000-4-6, conducted RF immunity Power ports, 3V/m 80% AM (1 kHz), 0.15 – 80 MHz
EN 61000-4-11, Voltage dips and interruption AC power ports:
10 & 100 ms, interruption
10 ms, 30% reduction
100 ms, 60% reduction
5000 ms, >95% reduction
+30% above & –20% below rated voltage
EN 55022, radiated RF emission Enclosure Class B
FCC part 15, radiated RF emission Enclosure Class B
EN 55022, conducted emission AC power ports, class A
DC power ports, class B
EN 55022, conducted emission AC power ports, class B
• Safety
EN 60950-1, dielectric strength UL/IEC/EN 60950-1, IT equipment
• Climatic
Temperature, operating –20 to +55ºC (–4 to +131ºF)
Temperature, storage –40 to +85ºC (–40 to +185ºF)
Humidity, operating 5 to 95 % relative humidity
Humidity, storage 5 to 95 % relative humidity
• Enclosure
Enclosure Pressed steel
Dimensions (W x H x D) 239 x 40 x 159 mm (9.4 x 1.6 x 6.2 inches)
Weight 0.9 kg
Degree of protection IP 40
Cooling Convection
Mounting Horizontal on 35 mm DIN-rail or flat on level surface
• Interface specifications, power
Rated voltage 11 – 28 VDC
Operating voltage 11 – 28 VDC
Rated current 1500 mA @ 12 VDC
Rated frequency DC
• Interface specification, RS-232
Electrical specification EIA RS-232
Data rate 300 bit/s to 115.2 kbit/s
Data format 7 or 8 data bits, Odd, even or none parity, 1 or 2 stop bits
Protocol Transparent, optimised by packing algorithm
Circuit type SELV
Transmission range 15 m / 49 ft
Connection 25 pin D-sub female
Shielded cable Not required
Conductive housing Yes
Number of ports 4
• Interface specifications, 10/100 BaseTX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type SELV
Transmission range 100 m / 328 ft
Isolation to All other
Connection RJ-45 auto MDI/MDIX
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Conductive housing Yes
Number of ports 4
• Interface specification, Antenna
Frequency bands 850 MHz – 2100 MHz
Connection SMA female, impedance: 50 ohm
• Interface specification, SIM
Electrical specification 3 volts SIM supported
Number of slots 2
• Interface specification, USB
Electrical specification USB 2.0 host interface
Data rate Up to 12 Mbit/s (full-speed mode)
Circuit type SELV
Maximum supply current 500 mA in total for both ports
Connection USB receptacle connector type A
Number of ports 2
• Interface specification, DSL
Data rate 50 Mbit Downlink, 3 Mbit Uplink
Protocol LLC/VC-MUX encap Ethernet, PPPoA, PPPoE, IPoA
Connection RJ-11
DSL, Standard/Annex ITU-T G.992.1 (ADSL) / A,B (non overlap)
ITU-T G.992.3 (ADSL2) / A,B,I,J,L,M (non overlap)
ITU-T G.992.5 (ADSL2+) /A,B,I,J,M (non overlap)
ANSI T1.413 / N/A
Shielded cable Not required, except when installed in Railway applications as signalling and telecommunications apparatus and located close to rails.
Number of ports 1

Related Product

Managed Industrial Ethernet Switch Viper-408
Industrial Ethernet Extender DDW-220
Managed Industrial Ethernet Switch VIPER-112
Industrial Ethernet Extender Wolverine DDW-222
Water and wastewater | Road | Rail trackside | On board rail | Oil and Gas | Maritime and offshore | Factory automation | Energy | Building automation
Copyright © Gigantika All Rights Reserved.